STANDING & CHINA HAT PILOT ADJUSTMENT PROCEDURE

NOTE: Caution must be exercised during the initial installation and/or conversion of standing or china hat pilots to ensure that the pilot valves are not wide open.
1. The main gas valve should be “OFF” for at least five minutes to allow any accumlated gas to escape the combustion chamber.
2. Gently remove the control knobs and the front apron panel to the unit.
3. Remove spider rings, open top Inflatable Water Slides grates, and locate the pilots.
4. Follow the pilot feed tube back to the manifold and locate the pilot adjustment valve.
5. With a small flat-tipped screwdriver adjust the valve to its minimum position, (maximum clockwise)
6. Ensure that the thermostat or manually operated controls are in the “OFF” position.
7. Turn on the gas. While holding a match close to the pilot head, slowly open the pilot valve (counter-clockwise) until the pilot head lights.
8. Properly adjust pilot flame for the correct height. (See Fig. 5)